Mass Calling Thresholds (MAS) Field Descriptions |
||
Field/Object |
Descriptions |
Valid Values/Actions |
CCS Network |
Identifies the Common Channel Signaling (CCS) Network. |
Required field. 2 alpha characters. Both Input and Output field. |
Threshold Level |
Identifies the Threshold Levels supported. |
2 numeric characters. Valid Values: 1 – 15. Output Field. |
Number of Lines |
Specifies the number of lines per destination number associated with each threshold level class 1 through 14. The threshold level 15 entry contains the word STUDY. |
4 numeric characters. Valid Values: 1 – 9999. |
Surveillance |
Specifies the number of call attempts in a 150 second period that will put a number under surveillance. Surveillance threshold must be less than Control threshold for the same Threshold Level class. It is recommended that the Surveillance threshold value be 100 below the corresponding Control threshold value for the same threshold level. |
Required field. 5 numeric characters. Valid Values: 50 – 19999. |
Control |
Specifies the number of call attempts in a 150 second period that will put the number under control. Control threshold must be greater than Surveillance threshold for the same Threshold Level class. |
Required field. 5 numeric characters. Valid Values: 51 – 20000. |
Initial Gap Interval |
Specifies the Gap Interval to be used during the first 150 seconds of control. After the initial 150 seconds, the Gap Interval is dynamically adjusted to the traffic load. Initial value is 1. Warning: An Initial Gap Interval of "0" will deactivate all automatic controls. |
Required field. 2 numeric characters. Valid Values: 0 – 15. |